Test plant personnel’s footwear - don’t be in for a shock

6 February 2020

Through their own movement people can generate large amounts of static charge if they are not grounded. Over 30,000 volts can be carried by people who are completely unaware that they themselves are the potential source of an electrostatic spark discharge that could ignite a flammable atmosphere.

Discharges of static electricity have been identified as an ignition source for a broad range of processes that cut right across a wide selection of industry groups with both plant equipment and personnel based operations.

Static charge accumulation on workers can be prevented by issuing them with footwear that is designed in accordance with EN 20395:2011 and ASTM F2413 (2018) safety standards or recommended practice documents like IEC 60079-32-1 and NFPA 77 that incorporate static dissipative properties in the structure of the footwear.

Static dissipative footwear is designed to prevent hazards that may arise due to excessively high footwear resistance with respect to ground. Regular testing of static dissipative footwear is strongly recommended to ensure the static dissipative properties of the shoes do not change during the duration of their use. The provision of footwear to plant personnel only reduces the risk if properly maintained, and this cannot be detected by visual inspection of the shoes alone. It should therefore be a fundamental requirement of organisations that have employees handling flammable and combustible materials in hazardous environments to ensure that the product is capable of fulfilling its designed function of dissipating electrostatic charges.

There is an obligation to perform electrical resistance tests via in-house footwear testers. The Sole-Mate II tester from Newson Gale provides a time efficient and cost effective method of ensuring personnel operating in hazardous areas are wearing static dissipative shoes that are capable of preventing electrostatic charge accumulation on their bodies. The system tests the condition and measures the resistance of the footwear to ensure static is capable of dissipating from personnel through their shoes to ground.

The Sole-Mate II testing station is typically located at the entrance to a hazardous area and plant personnel are afforded a quick ‘pass’ or ‘fail’ reading instantly. If the resistance of the shoes is too high, the Sole-Mate II tester will indicate that the shoes have failed the test via a red LED and buzzer alarm. If the shoes pass the test a green LED will indicate to the operator that the shoes are fit for purpose. For those companies that want to interlock the system to certain areas of their facility with entry access or audible alarms, an integral volt free relay contact makes it possible for the system to prevent access to a hazardous area without a pass reading on the tester, indicating that only suitable footwear is being worn upon entry.

It is not uncommon to find that footwear fails; after-all that is what the tester is designed to do. If footwear fails due to conditions – these present a risk as it indicates there is not a dissipative path through the person to ground to the required standard (for example, IEC EN 20345) and this presents a risk to operators and other plant personnel on site.

It is important to consider factors that could affect the resistance between the test button and foot plate. The electrical resistance of static dissipative footwear can be changed significantly by a number of factors. To find out what some of these are, click here to be taken to the full application spotlight document.

The Sole-Mate II footwear tester is just part of the static grounding and bonding equipment available from Newson Gale. Newson Gale offers a wide range of static grounding and bonding equipment which is made to provide optimum safety in explosive atmospheres for a variety of process applications. The Newson Gale range prevents static charge accumulation by using practical and innovative design, and ensures effective static control on three levels – grounding and bonding clamps, visual verification systems and interlockable control systems.